Skip to product information
1 of 11

Aerotate

XT90 Distribution Board

XT90 Distribution Board

Regular price €30,00 EUR
Regular price Sale price €30,00 EUR
Sale Sold out

without tax

The XT90 Distribution Board splits one XT90 supply into four XT90 outputs. Plus and minus run on solid copper pours on all four layers of the board, with no traces. Bare copper pads at both ends take M4 ring lugs on 6–8 AWG wire, so a battery lead or a power supply can be bolted on without an XT90 plug, or a second board chained on.

Features

  • 1 × XT90 male (input), 4 × XT90 female (outputs), Amass XT90PB
  • 4 × pad for an M4 ring lug on 6–8 AWG, plus and minus at both ends
  • Up to 40 A total, up to 30 A per output
  • Up to 60 V DC
  • 4-layer board, 35 µm copper on every layer
  • Polarity printed at every connector
  • 4 × M3 mounting holes

Specifications

Input 1 × XT90 male
Outputs 4 × XT90 female
Ring-lug pads 4 × Ø13 mm, hole Ø4.5 mm, for M4 ring lugs on 6–8 AWG, 1.2 N·m
Current per XT90 output 30 A continuous
Total current (bus) 40 A continuous
Operating voltage ≤ 60 V DC
Bus resistance ≈ 0.75 mΩ per pole (calculated)
Operating temperature −20 °C to +85 °C; above 60 °C ambient reduce current by 1 %/K
Board 98 × 30 mm, 1.6 mm FR4, 4 layers, 35 µm copper on every layer
Height above board 20.7 mm (XT90 male), 19.7 mm (XT90 female)
Overall height 23.5 mm (incl. 1.2 mm solder pins below)
Mounting 4 × Ø3.2 mm for M3, 44 × 23 mm apart

In the box

1 × XT90 Distribution Board, assembled and soldered. Cables, ring lugs and screws are not included.

Notes

  • All outputs are in parallel on one bus. The board has no fuse and no reverse-polarity protection: fuse the source.
  • The sum of all outputs must not exceed 40 A.
  • Keep the plus and minus ring lugs from touching under the board.
  • For safety extra-low voltage up to 60 V DC only.
  • Do not dispose of in household waste (electrical equipment under WEEE).
View full details